DFV FAULT RECORDER ELECTRICAL NETWORK ANALYSER BATTERIE TESTING SYSTEM ANALYSER POWER QUALITY RECORDER TRANSCIENT EVENT

 

 

Sale Hiring Services Reports of checking Organization of formations

ZA RAVENNES LES FRANCS
Tel 33 (0) 3 20 69 02 85
Fax 33 (0) 3 20 69 02 86
2 Avenue Henri Poincaré
BP 80009
59588 BONDUES
CEDEX FRANCE

Email : contact@dfv.fr

Back to Home Page

Disturbance Fault recorder (DFR) Electrical Network Analyser Recorders (Voltage, Current, Power, Harmonics, temperatures, pressure …) Real-time electrical network Analyser BSCOPE Automatic Battery tester (up to 249 cells) Chronometrer (protection relay verification… )

 

CHA20 Chronometer

This equipment is a digital chronometer wich allows to measure time between 2 pulses generated either by a dry contact, by a TTL input, or by an AC or DC voltage.It is used to verify protection relays. CHA20 is fitted in a metallic box size 150 x 260 x 340 Front panel : 6 digits chronometer and Led indicated that CHA20 is ready. Range switch (1/100 or 1/1000 second) Mode switch (single or multiple measures) RAZ switch Start/stop mode switch 2 Input channels (A and B) For each channel : one dry contact input one TTL input (DC courant input from 1,5 to 25 V) one voltage input (DC or AC voltage from 15 to 600 V) A build-in battery allows a 2 hours working Optionnal flight case

 

BATCAT Automatic battery tester BA24

BATCAT BA24R BATCAT BA24 Verify each cell of a battery during charge or discharge. Allow testing up to 249 cells Test every king of battery (Pb, CdNi …) Detect bad cells Measure the cells every 10 seconds High accuracy (± 2mV) Data are stored in a dataBase on a PC Issue an alarm when a threshold is reached Measure Ambiant or Electrolyt temperature Measure charge/discharge current Automatic test report

 

Disturbance Fault recorders (DFR), Network analysers
(APR4U4I, APRV, APR16).

APRV APR16 APR4U4I Undervoltages and overvoltages recording (Sampling rate 6400Hz) Harmonics (up to 63rd) Trend mode recording : RMS Values, harmonics, homopolar/direct/reverse components, active, reactive power. Application examples : Feeders monitoring (current, voltage, protection relay) Power supply monitoring Startup sequence recording (motors …) Power generator and UPS All the products (APRV, APR16, APR4U4I) can be programmed and managed remotely. Storage capacity : More than 10000 events and 2 years for trend mode recording 8/16 analog channels and 16/32 digital channels Colour LCD screen and 84 keys keyboard Portable analyser with 8 analog channels (4 voltages and 4 currents) and 4 digital channels 8/16 analog channels (direct input or remote via fibre optic) and 16/32 digital channels. Upgradable up to 128 analog channels and 256 digital channels. 19" rack mounting

 

 

BATCATWIN Windows software for BATCAT

DFV Technologie presents the new windows software to control automatic battery controler BATCAT. This program which is full Windows compatible improves this powerfull tool (Report manager, backup data, file manager …) Full compatible with the two BATCAT (PV99 et BA249) Windows 95, 98 et NT4 compatible Copy / Paste functions Export data in EXCEL Full compatible with MSDOS LOGBATPC files (batteries, trial, measurements) Storage compression allowing very long test No storage limit Storage in real time on hard disk (No loss of data in case of system/PC failure) Can display up to 4 cells on a curve Zoomin and zoomout Display of many curves simultaneously (windowing) Colour, scales customization Batteries, trials and measurement are displayed in a file manager with a previewin the right part of the window.

 

APRWIN Analysis and communication software for Disturbances Fault Recorders / Network analysers APR8, APRV, APR16 and APR4U4I

Fully compatible with the range of product APR : APR8, APR16, APR4U4I and APRV Operates under Windows 95/98/NT4/XP operating system Analysis on PC of recorded events on APR 3 modes : recorder (trend mode) BF mode HF mode : spikes (APR8HF) Local or remote communication with one or many APRs. Transfert of events Programming of APR Real time measurements Multiple APRs management Analog and logical channel management (ingoing and outgoing feeders) BF recording with harmonics analysis

 

BSCOPE Real-time electrical network Analyser

RMS, active, reactive, apparent power displaying. Reverse, direct, homopolar voltages/ currents displaying Phasis controler 8 Channels Oscilloscop Harmonics analyser (up to 63 + THD) 4 voltage channels up to 240V (Easy connection using ADAPTESSAILEC-U) 4 5V channels (Used to measure currents) No risk of opening currents circuits using ADAPTESSAILEC-I, currents clamps or CAPTFLEX. Monitored by serial RS232 link on PC with Windows software (95/98/NT4/ 2000/Millenium/XP). Delivered in a flight case (Accessories not provided). AdaptEssailec-U AdaptEssailec-I CAPTFLEX Current clamp Real time signal viewing Real time Harmonics analyser (up to 63 + THD)

 

VBSCOPE Real-time electrical network Analyser

RMS, active, reactive, apparent power displaying. Reverse, direct, homopolar voltages/ currents displaying Phasis controler 8 Channels Oscilloscop Harmonics analyser (up to 63 + THD) 4 voltage channels up to 240V (Easy connection using ADAPTESSAILEC-U) 4 current channels (5V) No risk of opening currents circuits using ADAPTESSAILEC-I, currents clamps or CAPTFLEX. Rapid connection with circular plug Copy function for word report Monitored by integrated PC Delivered in a flight case AdaptEssailec et SECURA -U AdaptEssailec et SECURA -I Current clamp Real time signal Real time Harmonics analyser (up to 63 + THD)

 

 

 

Fault recorder electrical network analyser DISTURBANCE FAULT RECORDER batterie testing system batterie analyser power quality recorder transcient recorder event recorder

BATTERY MONITORS BATTERY MONITORING BATTERY TRAINING BATTERY TEST BATTERY MAINTENANCE BATTERY TESTING.